Tea-Dust-Extraction-System_2Tea-Dust-Extraction-System
Industrial ducted systems fabricated and installed in compliance with SMACNA (Sheet Metal and Air Conditioning contractors National Association) and AS 4254-2002 Ductwork for air handling systems in buildings

Capabilities:

•    Rectangular Industrial Duct Construction (low and high pressure fabrication)
•    Round Industrial Duct Construction (low and high pressure fabrication)
•    HVAC Duct Construction Standards
•    Internally or externally insulated ducting

Construction Materials ranging from 0.8mm thickness up to 6mm thickness in:

Mild steel, galvanised steel, aluminized steel, zinc-anneal, Stainless steel and aluminium

Construction Method (pending on the application / scope of works):

Spot welded and internally sealed, Pittsburgh seam, Lock seam, continuously seal welded (general purpose welding) coded welding / welding procedures

To find out how we can best help your business with it’s ducting requirements.

Contact us on +61 3 9720 4475